To obtain documents, log on:
:
Not registered? Register me now
 

Public Higher Education Bulletin

 
University of Illinois at Urbana-Champaign
QBS #20289

Request for Professional Services Qualifications (QBS): Parking Decks C7 & C10

This procurement has been cancelled
Published Wednesday December 25, 2002
 
First published Tuesday December 24, 2002
Qualifications and supporting materials will be accepted at the address below until 4:00 PM, Wednesday January 15, 2003:
University of Illinois at Urbana-Champaign
207 Henry Administration Building
506 South Wright Street
Urbana, IL 61801-3684

Description of Project: University of Illinois at Urbana-Champaign parking decks C7 & C10 are multi-story, concrete and brick structures constructed in 1970. UIUC desires to undertake structural rehabilitation of these decks to insure efficient and safe use of these structures for an additional 20+ years. Additionally, UIUC wishes to make improvements to both structures. The subject improvements will include exterior masonry skin repair, signage/lighting upgrades, safety upgrades to the stair towers, installation of windows in the stair towers, addition of water service for cleaning purposes and surface membrane replacements. Furthermore, UIUC desires a rear (south fa�ade) exit be incorporated into parking deck C7.

Prior to UIUC conducting the rehabilitation of parking decks C7 & C10, it will be necessary to undertake a feasibility study which will contextually and graphically present the following data:

  • Structural and exterior skin assessment identifying deficient, damaged, and deteriorated areas.
  • Assessment of signage, lighting, stair tower safety, and traffic membrane deficiencies.
  • Identify most appropriate location and techniques for incorporating stair tower windows and water service in C7 & C10 and a rear exit in deck C7.
  • Recommendations for physical improvements and upgrades to correct identified faults and deficiencies.
  • Project budget to achieve recommended improvements and upgrades.
Subject to the availability of funds, the selected engineer will be employed for the remaining phases of the project.

Firms should submit 6 copies of the following: a letter of interest, a copy of its CDB prequalification letter, and a 255 form (use CDB SF 255 dated 6/25/02) by 4:00 p.m., Wednesday, January 15, 2003, addressed to:
University of Illinois
Division of Planning, Construction & Maintenance
1501 Oak Street
Champaign, IL 61820
Attention: (Roland Kehe)
Email address:rkehe@uiuc.edu

Engineer selection will be consistent with the Architectural, Engineering, and Land Surveying Qualifications Based Selection Act (30 ILCS 535/1).

Only those firms which meet the following qualifications will be considered for selection:

  • Licensed to practice as an Engineer in the State of Illinois
  • Prequalified with the State of Illinois Capital Development Board
  • Registered and authorized to do business in the State of Illinois
  • Utilization of AutoCAD compatible system
(Submitted by Katharine Kral, State Purchasing Officer.)

Selection will be consistent with the Architectural, Engineering, and Land Surveying Qualifications Based Selection Act (30 ILCS 535/1).

Bulletin Navigation

 
No documents are available.